Product Information: D- & L-Luciferin
Product No. 260159 / 260201 / 260313 / 260401
QUALITY CONTROL PROCEDURES - Biochemical performance
The biochemical performance of D-luciferin is assayed at 25°C by an automatic procedure using a Berthold Luminometer. The assay is based on standardized preparations of all components (luciferase, ATP, buffer etc.) required for the measurement. The light emission values obtained with 1.000 and 0.250 mg/mL of D-Luciferin and compared with a reference lot of D-Luciferin.
Actual results for 5 samples from a typical lot, in the absence of substrate inhibition and non-competitive inhibitors, will approach or exceed 100%. With test and reference lots of similar qualities a value around 100% is expected.
Table 1: Biochemical performance of D-Luciferin
| Reference is used in concentration of 0.200 mg/mL | Test 0.200 mg/mL |
| Lot No.1021 | 101.0 ± 1.9% |
| Specification | > 97.0% |